Install Anti-Tip Bracket - KitchenAid W11114334B Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Partially close the door to engage the
door latch locks. The door will stop at
this point.
Replace the Door
To replace the oven door(s), locate the slots in the oven
cavity for the hinge locks and repeat the steps above in
reverse order. Make sure the door closes properly and there
is no interference from the door latch. If necessary, remove
the door and repeat the steps above. If power is connected
to the range, open and close the door to make sure the oven
light comes on and goes off appropriately.
The range is equipped with leveling legs and rollers. Once
the range is removed from the shipping pallet, make sure the
leveling legs are not touching the floor and use the rollers
to move the range into position. Always cover the flooring
surface to avoid damage to the floor. Do not roll the range
directly on the floor.
10
1. Determine which mounting method to use: floor or wall.
2. Determine and mark centerline of the cutout space. The
A

Install Anti-Tip Bracket

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death
or serious burns to children and adults.
If you have a stone or masonry floor, you can use the
wall mounting method.
mounting bracket must be installed on the left side of the
cutout. Position mounting bracket in cutout as shown in the
following illustration.
Measurement B:
30" (76.2 cm) ranges: 13" (33.0 cm)
36" (91.4 cm) ranges: 16" (40.6 cm)
48" (121.9 cm) ranges: 22" (55.9 cm)
Measurement C:
Optional distance from back wall. If back wall is constructed
of a combustible material and a backguard is not installed, a
6" (15.2 cm) minimum clearance is required for all models.
Install anti-tip bracket accordingly.
C
B
A. Centerline
B. Centerline of cutout to outside
edge of anti-tip bracket
C. Back wall to back of range
A

Publicité

Table des Matières
loading

Table des Matières