INSTALLATION
Installing/Replacing the lamp
For the installation, you need one EHJ 24 V/250 W G-6,35 lamp.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1: Unscrew the fixation screws Y and Z of the lamp system and carefully remove it from the
housing.
Step 2: If replacing the lamp, remove the old lamp from the lamp holder.
Step 3: Insert the lamp into the lamp holder.
Step 4: Replace the lamp system in the housing and tighten the fixation screws.
Step 5: Adjust the lamp as described under lamp adjustment.
Lamp adjustment
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened cover!
The lampholder is aligned at the factory. Due to differences
between lamps, fine adjustment may improve light performance.
Strike the lamp, set the dimmer intensity onto 100 % and focus the
light on a flat surface (wall). Center the hot-spot (the brightest part
of the beam) using the 3 adjustment screws "A, B, C". Turn one
screw at a time to drag the hot-spot diagonally across the projected
image. If you cannot detect a hot-spot, adjust the lamp until the
light is even.
To reduce a hot-spot, pull the lamp in by turning all three screws
"A, B, C" clockwise ¼-turn at a time until the light is evenly
distributed.
22/55