Before
charging
While
charging
Charge
Charging
indicator
complete
lamp
(RED /
Overheat
GREEN)
standby
Charging
impossible
(2) Regarding the temperatures and charging time of the rechargeable battery
The temperatures and charging time will become as shown in Table 3.
Type of battery
Temperatures at which the
battery can be recharged
Charging voltage
Charging time, approx. (At
20°C)
1.3 Ah
Battery
1.5 Ah
2.0 Ah
2.5 Ah
3.0 Ah
4.0 Ah
5.0 Ah
6.0 Ah
8.0 Ah
Charging voltage
USB × 2
Charging current
NOTE
○ The battery charging times may increase depending
on the ambient conditions and battery conditions.
The battery charging times apply to charging one
battery on its own. When charging multiple batteries,
the total charging time will be the sum of the individual
charging times.
○ Charging time will increase if the ambient temperature
is below 0°C.
5. Disconnect the charger's power cord from the
receptacle.
6. Hold the charger fi rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after
use, and then keep it.
Indications of the charge indicator lamp
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(RED)
Lights
Lights continuously
(RED)
Lights continuously
Lights
(GREEN)
(Continuous buzzer sound: about 6
seconds)
Lights for 0.3 seconds. Does not light
Blinks
for 0.3 seconds. (off for 0.3 seconds)
(RED)
Lights for 0.1 seconds. Does not light
for 0.1 seconds. (off for 0.1 seconds)
Flickers
(RED)
(Intermittent buzzer sound: about 2
seconds)
Charger
V
14.4
BSL14xx series
(4 cells)
min.
BSL1415S : 15
BSL1415 : 15
min.
BSL1415X : 15
min.
BSL1420 : 20
min.
BSL1425 : 25
min.
BSL1430C : 30 BSL1430 : 20 BSL1830C : 30 BSL1830 : 20
min.
BSL1440 : 26
min.
BSL1450 : 32
min.
BSL1460 : 38
min.
V
A
Table 2
Table 3
UC18YTSL(S)
Li-ion
0°C–50°C
BSL18xx series
(8 cells)
(5 cells)
BSL1815S : 15
BSL1815 : 15
BSL1815X : 15
BSL1820 : 20
BSL1825 : 25
BSL1840 : 26
BSL1850 : 32 BSL36A18 : 32
BSL1860 : 38
5
Total 2
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might be
low when using them the fi rst and second time. This is
a temporary phenomenon, and normal time required
for recharging will be restored by recharging the
batteries 2–3 times.
How to make the batteries perform longer.
(1) Recharge
the
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery. If
you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
13
Plugged into power source
Battery overheated. Unable to
charge. (Charging will commence
when battery cools)
Malfunction in the battery or the
charger
18
Multi volt
series
(10 cells)
(10 cells)
BSL36B18 : 52
batteries
before
they
English
10.8 V–12 V
Peak
BSL12xx
series
(3 cells)
BSL1225M : 37
BSL1240M : 60
become

Publicité

loading