After you connected the effect to the mains, the DMX-GIGASTROBE starts running.
On the rear panel ot the DMX GIGASTROBE there are two controls to adjust the flash frequency (1-12
flashes per second) and the dimming level (0-100%).
For manual control, all DIP-switches have to be set to 0.
DIP-SWITCHES
1 2 3 4 5
0 0 0 0 0
DMX-control via the connected DMX-controller.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The protective shield has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
There are no serviceable parts inside the device except for the lamp. Maintenance and service operations
are only to be carried out by authorized dealers.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.
Speed and dimmer level adjustable
via the controls on the rear panel
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
DO NOT OPEN FOR 5 MINUTES AFTER SWITCHING OFF!
CAUTION!
15