nected to a mains socket has a low power consump-
tion.
G
Do not set the receiver or the camera into operation,
and immediately disconnect the corresponding
charg er or plug-in power supply unit from the mains
socket if
1. there is visible damage to one of the units,
2. a defect might have occurred after a drop or simi-
lar accident,
3. malfunctions occur.
The units must in any case be repaired by skilled
personnel.
G
For cleaning only use a dry, soft cloth, by no means
chemicals or water.
G
No guarantee claims for the units and no liability for
any resulting personal damage or material damage
will be accepted if the units are used for other pur-
pos es than originally intended, if they are not correctly
connected, operated, or not repaired in an expert way.
If the units are to be put out of operation de-
finitively, take them to a local recycling plant
for a disposal which is not harmful to the envi-
ronment.
3
Applications
The set of units AV-422SET consists of a 2.4 GHz wire-
less camera, the corresponding receiver, a charger for
the wireless camera, and a 8 V power supply unit for the
receiver. It serves for setting up a wireless video sur-
veillance system. For this purpose only a colour monitor
is additionally required. For the audio transmission a
microphone has been integrated into the colour camera.
The transmission range largely depends on the
local conditions. Without any obstacles between cam-
era and receiver it may be up to 100 m. However, in
buildings the range is reduced to approx. 20 m by walls
and ceilings, depending on their condition. By using an
antenna with gain at the receiver, the range can, how-
ever, be increased many times over.
3.1 Conformity and Approval
Herewith, MONACOR INTERNATIONAL de clare that
the set of units AV-422SET is in accordance with the
basic re quirements and the other relevant regulations
of the directive 1999 / 5 / EC. The declaration of confor-
mity can be found in the Internet via the MONACOR
INTERNATIONAL home page (www.monacor.com).
The set of units is licence-free and generally ap -
proved for operation in EU and EFTA countries.
4
Operation
4.1 Placing the camera and receiver
Practical experience has shown that an optimum
reception is achieved when placing the units at a height
of minimum 1.5 m to 2 m above the ground. Prior to the
final mounting, a trial run is recommended as the trans-
GB
9