OMNIA ST 3.2
9.2 Service parameters table
Menu
Menu
Level 1
Level 2
1.1 Dhw Mode
1.2 Disinfect
1.3 Dhw Priority
1.4 Dhw Pump
1.5 Dhw Priority Time Set
1.6 Dt5_On
1.7 Dt1S5
1.8 T4Dhwmax
1.9 T4Dhwmin
1.10 T_Interval_Dhw
1.11 Dt5_Tbh_Off
1 Dhw Mode
For Serviceman
Settings
1.12 T4_Tbh_On
1.13 T_Tbh_Delay
1.14 T5S_Di
1.15 T_Di_Hightemp
1.16 T_Di_Max
1.17 T_Dhwhp_Restrict
1.18 T_Dhwhp_Max
1.19 Dhw Pump Time Run
1.20 Pump Running Time
1.21 Dhw Pump Di Run
2.1 COOL MODE
2.2 t_T4_FRESH_C
2.3 T4CMAX
2.4 T4CMIN
2.5 dT1SC
2.6 Reserved
2.7 t_INTERVAL_C
2 Cool Mode
For Serviceman
Settings
2.8 T1SetC1
2.9 T1SetC2
2.10 T4C1
2.11 T4C2
2.12 ZONE1 C-EMISSION
2.13 ZONE2 C-EMISSION
Menu
Menu
Level 3
Level 4
Cod. 3541V991 - Rev. 01 - 10/2021
Description
DHW ENABLE YES/NO
ANTILEGIONELLA ENABLE
DHW MODE PRIORITY- heating/coolig or DHW
To enable DHW recirculation pump
1= present, 0= not present
To enable minimum working time for DHW mode
and plant
Hysteresis of DHW boiler set point
Set point temperature difference between the
water sent to the coil of DHW boiler and the DHW
boiler temperature.
The maximum ambient temperature that the heat
pump can operate at for domestic water heating
The minimum ambient temperature that the heat
pump can operate for domestic water heating
The minimum compressor off time interval
between 2 starts in DHW mode
the temperature difference between T5 and T5S
that turns the electric heater for DHW boiler off.
Maximum outdoor air temperature at which
the DHW boiler electric resistance (TBH) can
operate.
the time that the compressor has run before
starting the electric heater for DHW boiler
DHW storage tank temperature holding time at a
value greater than "T5S_Di" in the anti-legionella
function
the time that the highest temperature of dhw
water tank in the DISINFECT function will last
the maximum time that disinfection will last
the operation time for the space heating/cooling
operation.
the maximum continuous working period of the
heat pump in DHW PRIORITY mode.
Enables / disables the timer of DHW recirculation
pump
t_pumpDHW - time that the DHW recirculation
pump will keep running for
Enables / disables the DHW circulation pump
during the anti-legionella function
Enables or disables the cooling
mode:0=NON,1=YES
The set point update time calculated from the
climatic curve for the cooling mode
The highest ambient operation temperature for
cooling mode
the lowest ambient operating temperature for
cooling mode
the temperature difference for starting the heat
pump(T1)
Reserved
Time between stop and start of the compressor
in cooling mode
The setting temperature 1 of climatic curve n°9
for cooling mode.
The setting temperature 2 of climatic curve n°9
for cooling mode.
The outdoor air temperature 1 of climatic curve
N°9 for cooling mode.
The outdoor air temperature 2 of climatic curve
N°9 for cooling mode.
The type of zone1 terminal for cooling mode:
0=FCU(fan coil unit): 1=RAD.(radiator):
2=FLH(floor heating)
The type of zone2 terminal for cooling mode:
0=FCU(fan coil unit): 1=RAD.(radiator):
2=FLH(floor heating)
Lower
Upper
Unit of
Resolution
limit
limit
measure
0
1
1
/
0
1
1
/
0
1
1
/
0
1
1
/
0
1
1
/
1
30
1
°C
5
40
1
°C
35
43
1
°C
-25
30
1
°C
5
5
/
min
0
10
1
°C
-5
50
1
°C
0
240
5
min
60
70
1
°C
5
60
5
min
90
300
5
min
10
600
5
min
10
600
5
min
0
1
1
/
5
120
1
min
0
1
1
/
0
1
1
/
0,5
6
0,5
hours
35
52
1
°C
-5
25
1
°C
2
10
1
°C
/
/
/
/
5
30
1
min
5
25
1
°C
5
25
1
°C
-5
46
1
°C
-5
46
1
°C
0
2
1
/
0
2
1
/
EN
Default
value
1
1
1
0
0
5
10
43
-10
5
5
5
30
65
15
210
30
90
1
5
1
1
0,5
52
10
5
/
5
10
16
35
25
0
0
117