For a complete range of accessories, see
www.metabo.com or the catalogue.
10. Repairs
Repairs to electrical tools must ONLY be
carried out by qualified electricians!
Contact your local Metabo representative if you
have Metabo power tools requiring repairs. See
www.metabo.com for addresses.
You can download a list of spare parts from
www.metabo.com.
11. Environmental Protection
Do not allow battery packs to come into contact with
water!
Discharge the battery pack in the power tool before
disposal. Prevent the contacts from short-circuiting
(e.g. by protecting them with adhesive tape).
12. Technical Data
Fig. L. We reserve the right to make technical
improvements.
U
=
Voltage of battery pack
n
=
No-load speed
0
Tightening torque for screwing:
M
=
Soft screwing application (wood)
1
M
=
Hard screwing applications (metal)
3
M
=
Adjustable torque
4
Max. drill diameter:
D
=
in steel
1 max
D
=
in softwood
2 max
D
=
in masonry
3 max
s
=
Max. impact rate
m
=
Weight (with the smallest battery pack)
G
=
Spindle thread
D
=
Chuck clamping range
max
Permitted ambient temperature during operation:
-20 °C (-4°F) to 50 °C (120°F) (limited performance
with temperatures below 0 °C (32°F)). Permitted
ambient temperature for storage: 0 °C (32°F) to
30 °C (86°F).
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the power tool and to compare
different power tools. The actual load may be higher
or lower depending on the operating conditions, the
condition of the power tool or the accessories.
Please allow for breaks and periods when the load
is lower for assessment purposes. Arrange
protective measures for the user, such as
organisational measures based on the adjusted
estimates.
Vibration total value (vector sum of three directions)
determined in accordance with EN 60745:
a
=
Vibration emission value
h, ID
(impact drilling in concrete)
a
=
Vibration emission value
h, D
(Drilling in metal)
a
=
Vibration emission value (screwing
h, S
without impact)
K
=
Uncertainty (vibration)
h, ...
Typical A-effective perceived sound levels:
L
= Sound-pressure level
pA
L
= Acoustic power level
WA
K
, K
=Uncertainty (noise level)
pA
WA
During operation the noise level can exceed
80 dB(A).
Wear ear protectors!
ENGLISH en
11