Télécharger Imprimer la page

Beta 1945S Notice D'utilisation Et Instructions page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
OPERATION MANUAL AND INSTRUCTIONS
ISTRUZIONI PER L'USO
KEY TO SYMBOLS
a: Air inlet 1/4" GAS
b: Stapler trigger
c: Safety trigger
d: Staple release point
Air supply connection
For correct use of the pneumatic tool, always keep to such maximum pressure as stated in the TECHNICAL DATA table and
measured at the tool inlet. Feed the pneumatic tool with clean, condensate-free air (picture 1). Excessively high pressure or
humidity in supply air results in shorter life for the mechanical parts and may damage the tool.
USE
How to fill magazine
Always disconnect the air supply before filling the magazine; this precaution will prevent the pneumatic tool from being
accidentally started.
During this operation, hold the pneumatic tool in such a way that it is not pointed to the operator or other people.
• Choose the type of staple to drive in according to the type of job required. You cannot load different types of staples
simultaneously.
• Do not drive in any deformed fixing parts, and only use such fixing parts as stated in the TECHNICAL DATA table.
• Place the pneumatic fixing machine in such a way as to prevent the fixing parts that are contained in it from falling accidentally
when the magazine is opened.
• To open the magazine, press the rear lever (picture 3); a spring will cause the magazine to open automatically.
• Fit the fixing parts into their seats (picture 4).
• Push the magazine as much as required to close it fully; the trigger will be released and locked automatically.
• Connect air supply to the pneumatic tool.
Start
Start operating the pneumatic fixing machine as follows:
• Firmly place the pneumatic fixing machine near the working area.
• Press the safety trigger; keep it pressed and then pull the trigger (picture 2). The pneumatic fixer will allow one "shot" at a time.
• For each fixing part driven ("shot"), pull the trigger, keeping the safety trigger pressed.
• Shots in sequence are not allowed.
• When the safety trigger is released, the pneumatic fixing machine stops and the trigger cannot be pulled.
Troubleshooting
Always disconnect air supply before checking the pneumatic tool for failures or cleaning it, and empty the magazine; this precaution
will prevent the pneumatic tool from being accidentally started.
FAILURES
Fixing part jammed
No fixing part is ejected
Fixing part cannot be fitted in
completely
Other failures
Periodically, depending on the frequency of use, clean the pneumatic tool. If any operation defects that cannot be dealt with
through the instructions should be shown, send the pneumatic tool to the repair centre.
12
e: Magazine release lever
f: Magazine
g: Staple set
h: Oil lubrication
POSSIBLE CAUSES
Fixing part loaded incorrectly.
Unsuitably sized fixing part.
Bits of glue or wood powder in
magazine or guide.
Low pressure in air supply
system.
Low pressure in air supply
system.
SOLUTIONS
Check that fixing machine has been correctly loaded
as follows:
1) Turn fixing machine upside down and release rear
lever (picture 3-4).
2) Open magazine and remove jammed staple.
3) Load staples and check that they slide easily.
4) Push magazine as much as required to close it
fully.
Connect air supply to fixing machine and operate it.
Check dimensions of fixing part by comparing them
with dimensions stated in TECHNICAL DATA table.
Remove bits of glue or wood powder.
− Check compressed air supply system.
− Check output pressure.
− Check compressed air supply system.
− Check output pressure.
− Contact repair centre.
EN
I

Publicité

loading