Regularly check the extension cables and replace them if
they are damaged.
Do not use any defective connection cables.
When working outdoors, only use extension cables especially
approved and appropriately labelled for outdoor use.
Do not set up any provisional electrical connections.
Never bypass protective devices or deactivate them.
Only hook up the machine by means of a fault-current cir-
cuit breaker (30 mA).
The electrical connection or repairs to electrical parts of
the machine must be carried out by a certified electrician or
one of our customer service points. Local regulations –
especially regarding protective measures – must be ob-
served.
Repairs to other parts of the machine must be carried out
by the manufacturer or one of his customer service points.
Use only original spare. Accidents can arise for the user
through the use of other spare parts. The manufacturer is
not liable for any damage or injury resulting from such ac-
tion.
C
o
m
C
o
m
Check that the machine is completely and correctly assem-
bled.
To avoid toppling, place the shredder on a firm horizontal
surface.
Do not place the equipment on ground which is paved or
surfaced with gravel.
The machine should only be operated in the open. Always
maintain a safe distance (at least 2 m) from walls or other
fixed objects.
Before each use, check
Connection cables for defects (cracks, cuts, etc.).
−
Do not use any defective cables.
There are no damage at the machine
−
(see safety instructions).
All screws are tight.
−
Mains connection
Compare the voltage given on the machine model plate e.g.
230 V with the mains voltage and connect the machine to the
relevant and properly earthed plug.
Only use extension cables with sufficient core cross-section.
Mains fuse
2500 W
16 A time-lag
Retaining basket
The integrated retaining basket is equipped with a locking
lever.
The retaining basket is unlocked and can be
disconnected from the device.
The retaining basket is locked and fixed connect-
ed to the device.
14
m
i
s
s
i
o
n
i
n
g
m
i
s
s
i
o
n
i
n
g
Switzerland
UK
13 A time-lag
On / Off switch
Do not use any device where the switch can not be switched
on and off. Damaged switches must be repaired or replaced
immediately by the customer service.
Switch on
I
Press "
".
Switch off
O
Press "
".
Restart protection in case of power
failure
In case of a power failure, the device switches off automatically
(zero-voltage initiator). To restart, press "
Motor protection
The motor is equipped with a safety switch and switches off au
tomatically when overloaded. After a cooling-down break (approx.
5 min), the motor may be restarted. Press the
1. reset button (motor protection)
I
2. "
" to restart.
Use a tamper or hook to remove jammed objects from the
hopper or ejection slot.
Always wait until the shredder has come to a complete
standstill before restarting it.
Electrical mains supply impedance
When conditions in the electrical mains supply are un-favourable,
voltage reductions for short periods can occur during the process
of turning on the equipment, which can adversely affect other
equipment (e.g., the flickering of a lamp).
No breakdowns are to be expected if the maximum, electrical
mains supply impedances given in the table are met.
Power consumption P
(W)
1
2500
I
" again.
Electrical mains supply
impedance Z
(Ω)
max
0.333