The "scan headend" per-
formed with TPE does not
detect any module
Input connectors
Impedance
IP output connector and programming
Input frequency
Input level
Input return loss
Tuning step
AFC
Gain of passage of self-demixing input
Max. number of modules to demix at the
input
LNB remote feeding
DiSEqC
Symbol rate
FEC
Output
MPEG information
Supported transmission protocols
Programming
Power supply tension
Max consumption
Operational temperature
Dimensions
GB: Technical data is nominal values and refer to an operating temperature of 5° C
Temporary absence of comu-
nication between the streamer
and the sub-rack
9. TECHNICAL SPECIFICATIONS
CONNECTORS
INPUT SIGNALS
± 3MHz (a 7.5Msym/s, -60dBm, C/N=10dB)
Depends on the frequency and level of the input
0/14/18V, 0/KHz, 00mA 14V – 100mA 18V
OUTPUT SIGNAL
Up to 1 digital encoded program in IP with single
UDP, RTP, SAP, SDP, PID filtering, PSI/SI parsing,
GENERAL
45
1.
Unplug and re-plug the TPE;
.
make a new "scan headend"
F (RF IN, RF OUT) connectors
75Ω
1 RJ45 connector
950 to 150MHz
40 to 84dBµV
> 11 on single module
> 9 with modules
1 MHz
0,8 - 1.7dB
signal
1.0
1 – 40 Msym/s
Auto (1/, /3, 3/4, 5/6, 7/8)
multicast address
Available MPEG information
Regeneration of PAT and PMT tables.
TPE e PC
0-40V ~ 50-60 Hz
11W
-10 to +45°C
35 x 130 x 40mm