4.
Mounting
The isolated standard signal conditioners are mounted on standard TS 35 rails.
5.
Electrical Connection
Terminal Assignments
1 Input +
2 Input –
3 Input +
4 Input –
5 Output +
6 Output –
7 Power supply
8 Power supply
Conductor cross-section max. 2.5 mm
Multi-wire connection max. 1 mm
(two wires with equal diameters)
AWG 30-12, tightening torque 0.7 Nm
The connected wires must be suitable for a
temperature of at least 75 °C.
WARNING!
Do not operate inputs for current and voltage simultaneously!
For applications with high working voltages, take measures to prevent
accidental contact and make sure that there is sufficient distance or insulation
between adjacent devices.
5.1 Power Supply
22 to 230 V AC/DC ± 10 %, 1 W, AC: 48 to 62 Hz, 2 VA
(overvoltage category II)
current
current
voltage
voltage
2
2