Gas pressure adjustment
Gas delivery adjustment on starting
• Connect a suitable pressure gauge to pressure point "A".
• Unscrew the pressure regulator "C", turning the adjustment screw anticlockwise.
• Turn the screw of regulator "B" fully anticlockwise (starting at max. pressure)
• Start the burner
• Check the valve gas outlet pressure with the pressure gauge.
• If necessary, reduce the gas pressure by operating the screw of the power regulator "D".
• If the operating gas delivery has to be further increased, turn the pressure regulator clockwise to
increase the gas delivery as required.
Key
A Outlet gas pressure point
B Power and ignition step regulator
C Pressure regulator
D Power regulator
Gas pressure adjustment SUN M10