1. OPERATING INSTRUCTIONS
1.1 Introduction
Dear Customer,
Thank you for choosing SUN M10, a Ferroli single-stage burner featuring advanced design, cutting-edge
technology, high reliability and quality construction.
SUN M10 is a gas burner whose compact size and original design make it suitable for use with the majority
of boilers available on the market. The care taken in its design and industrial production has resulted in
a well-balanced product with very low CO and NOx emissions and a very quiet flame.
1.2 Operating instructions
Once the burner is installed and correctly adjusted, its operation
is fully automatic without requiring any control by the user. In
case of anomalies or no fuel, the burner stops and shuts down
(red indicator on release button lit).
Make sure the room where the burner is installed is free of flamma-
ble materials or objects, corrosive gases and volatile substances,
and that it is not dusty. In fact, dust drawn by the fan sticks to
the blades and reduces the air flow rate or obstructs the flame
stability disk, affecting its efficiency.
Do not allow unskilled persons or children to tamper with the burner.
1.3 Maintenance
Service the burner periodically, at least once a year. Servicing must be performed by qualified personnel
as described in section 3.
1.4 Anomalies
If the burner fails to start and the red indicator on the release button is not lit, check that it is powered,
the heating system switch is turned on, the fuses are efficient and that there is a boiler heat demand.
If the burner has shut down (red indicator on release button lit), press the release button to restore
operation. The burner will try to ignite. If it shuts down again, make sure there is fuel and that the manual
valves on the gas supply pipe are open. If these checks are negative, contact the after-sales service.
In case of abnormal noises during burner operation, contact the after-sales service.
26
Cod. 3540G441 - 05/2009 (Rev. 00)
SUN M10
Burner
release
button
fig. 1
GB