50 cm
2 m
1
m
CHIMNEY CAPS - DISTANCES AND POSITIONING
Inclination of the roof
α α α α
15°
30°
45°
60°
20
(1) In case of flues side by side, a chimney cap must be
higher than the other one of at least 50 cm in order to avoid
pressure transfers between the flues themselves.
10 m
(1) The chimney cap must not show hindrances within 10 m from walls,
pitches and trees. Otherwise raise it of at least 1 m over the hindrance.
The chimney cap must exceed the ridge of the roof of at least 1 m.
>A
H min.
(1)ridge axis
α
Distance between the roof ridge
and the stack
A (m)
< 1,85 m
> 1,85 m
< 1,50 m
> 1,50 m
< 1,30 m
> 1,30 m
< 1,20 m
> 1,20 m
CARILLON 4:3 – CARILLON 16:9 – CARILLON CLASSIC
> _ A
0,5 m
(2)roof
Minimum height of the stack (measured from the
0,50 m above the roof ridge
0,50 m above the roof ridge
0,50 m above the roof ridge
0,50 m above the roof ridge
UNI 10683/98
outlet)
H (m)
1,00 m from the roof
1,30 m from the roof
2,00 m from the roof
2,60 m from the roof
7196755 Rev.09 – EN
Picture 6
Picture 7
Picture 8