Single-Bank Mode (Default)
NOTE: The Bank 1 Indicator flashes and the Bank 2 Indicator is blank
when you are using the unit in the Single-Bank Mode.
Connection
Maximum
Charge
Rate
Built-in battery
30A
clamps only
continuous
Multi-Bank Mode (Up to 2 Simultaneous
Connections — Banks 1 and 2)
Connection
Maximum
Charge
Rate
• Built-in battery
15A
clamps (Bank 1)
continuous
per Bank
• Clamp Cable
(the overall
Set with O-ring
charging
Connectors (sold
capability
separately)
is 30A
(Bank 2)
continuous
when both
battery banks
are active)
DXAEC80_DXAEC80CA_ManualENFRSP_082616.indd 13
Engine
Functions
Start
80A for 5
(All functions)
seconds
Battery Voltage
Check, Battery
Charging,
Battery
Reconditioning,
Alternator Check
and Engine Start
Engine
Functions
Start
Not
Battery Voltage
applicable
Check, Battery
Charging,
Battery
Reconditioning
and Alternator
Check
Charging the Battery
IMPORTANT: If a problem is encountered during the battery charging
process, refer to the "Indications and Faults – All Modes" section that
follows the battery charging directions.
Single-Bank Battery Charging
1. Plug the battery charger's AC Power Cord into a functioning
AC outlet. A beep will sound and the LCD Screen will show the
following:
The Bank 1 Indicator flashes to indicate that the unit is in Single-
Bank Mode (the default mode) and that Bank 1 is selected. (The
Bank 2 panel remains blank in Single-Bank Mode.) The empty
Battery Icon will light solid to indicate the built-in battery clamps
are not yet connected to a battery.
2. Connect the battery charger to the battery using the built-in battery
clamps, following the appropriate directions in the "Preparing to
Charge" section of this Instruction Manual.
If the clamps are properly connected with regard to polarity, a beep
will sound and the LCD Screen will show the following, indicating
the unit is in Standby Mode:
13
10/19/2016 3:58:06 PM