56
Under abnormal use;
i.e. leaving the machine without charging for a period of time - we advise that you follow these steps:
Battery Care
To ensure your machine remains at its maximum efficiency and prolong your battery
life, please follow the simple steps below:
Under normal daily usage:
Recharge batteries after each use regardless of machine operation time (see page 46).
Showing location of Viewing panel for charging-light sequence (Fig.56).
Signal (LED)
Red LED on
Orange LED on
Green LED on
Red LED flashing
followed by
Pause
Recharge the machine fully after its last use.
Do not leave the machine in a discharged state.
If the machine will be standing unused for a period of 30 days or more,
then batteries must be fully charged and battery fuses removed using the
Maxi fuse-puller provided, prior to this period.
Batteries should be recharged every three months.
Charge fully the day before you start using the machine again.
First Phase (constant current Mode)
Second Phase (Constant Voltage Mode)
Third Phase (Constant Voltage Mode) Charge Complete
Cooling Fan Locked > 1 flash between pause
Over Voltage Protection / Output Short Circuit / Battery Reverse Polarity
> 2 flashes between pause
Over Temperature Protection > 3 flashes between pause
Charge Time has exceeded 10 hrs during phase 1 or 2
> 4 flashes between pause
48