Mounting Of The Pump - Areas Of Risk - Lincoln Quicklub 203 DC Instructions De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

User Manual
Operating Instructions
Mounting of the Pump – Areas of Risk
According to pa ragraph 9.7. 8 of the ADR directive, vehicles
with hazardous goods type FL are divided into zones, ac-
cording to the EX prescriptions.
These are the correspondences:
- tank inside zone 0,
- fitting cabinet zone 1
- shut-off devices zone 1
- venting devices zone 1
ADR-2
Areas of ri sk
Page 6 of 22
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
ADR Installation, continuation
Zone 2 is loca ted a round zones 0 and 1.
The installation of the centralize d lubrication system is
allowed outside of zones 0, 1 and 2, only, whereby the
extension is not determined in the ADR directive.
Rega rding t his use the form to confirm the ADR-concurring
insta llation.
2.1EN-38002-I10
T -AD R-0 10a08

Publicité

Table des Matières
loading

Table des Matières