TECHNICAL DATA

MODEL
TYPE
OUTPUT
(1)
FUEL
- Net calorific value
- Absolute density
- Max. delivery
- Pressure at max. delivery
(2)
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE LEVELS
(3)
APPROVAL
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m s.l.m.
(2) Pressure at test point 16)(A)p.8, with zero pressure in the combustion chambre, with open gas ring 2)(B)p.16 an maximum burner output
(2) Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.

VARIANTS:

BURNER
Blast tube lenght mm

ACCESSORIES

(optional):
KIT FOR LPG OPERATION: The kit allows the RS 70-100-130/M burners to operate on LPG.
BURNER
OUTPUT kW
BLAST TUBE LENGHT mm
CODE
OUTPUT POWER REGULATOR KIT: Under modulating operation, the burner automatically adapts to one of an infinite number of firing rates
between the low and high flame output position, thus ensuring stable operating conditions in terms of temperature or pressure. Two components
should be ordered: • Power regulator to install to the burner; • probe to install to the boiler.
PARAMETER TO BE CHECKED
Temperature
Pressure
GAS TRAIN ACCORDING TO REGULATION EN 676 (with valves, pressure governor and filter): see page 18.
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.
MAX.
MIN.
kWh/Nm
Mcal/Nm
°C max
V1 - V2
RS 70/M
RS 100/M
RS 130/M
250
250
280
RS 70/M
242 ÷ 814
250
3010097
Range
- 100...+ 500°C
0...2,5 bar
0...16 bar
RS 70/M
828 T1
kW
465 - 814
400 - 700
Mcal/h
kW
135
116
Mcal/h
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
G25
10
8,6
3
8,6
7,4
3
3
0,71
0,78
kg/Nm
81
94
3
Nm
/h
mbar
10,3
15,2
• On-Off (1 stop min each 24 hours).
This burner is also fitted for the continuos operation, if it is equipped
with the control box LANDIS type LGK 16.333 A27 (interchangeable
with the burner control box Landis LFL 1.333).
• Progressive two-stage or modulating by kit (see ACCESSOIRES).
Boilers: water, steam, diathermic oil
°C
0 - 40
60
V
230 - 400 with neutral ~ +/-10%
Hz
50 - three-phase
rpm
2800
W
1100
V
220/240 - 380/415
A
4,8 - 2,8
230 V - 1 x 8 kV
I1 - I2
1 A - 20 mA
W max
1400
IP 44
90/396 - 89/336 - 73/23
dBA
75
CE
0085AQ0708
COUNTRY
IT-AT-GR-DK-FI-SE
ES-GB-IE-PT
RS 100/M
349 ÷ 1163
250
3010099
PROBE
Type
PT 100
Output probe
4...20 mA
6
RS 100/M
829 T1
698 - 1163
600 - 1000
150
129
G20
G25
10
8,6
8,6
7,4
0,71
0,78
116
135
9,3
13,7
2800
1500
220/240 - 380/415
5,9 - 3,4
1800
77
CATEGORY
II
NL
II
FR
DE
II
2ELL3B/P
BE
I
2E(R)B,
LU
II
RS 130/M
466 ÷ 1512
280
3010101
POWER REGULATOR
Code
Type
3010110
RWF40
3010213
3010214
GB
RS 130/M
830 T1
930 - 1512
800 - 1300
160
138
G20
G25
10
8,6
8,6
7,4
0,71
0,78
151
175
8,6
12,7
2800
2200
220/240 - 380/415
8,8 - 5,1
2600
78,5
2H3B/P
II
2H3P
2L3B/P
II
2Er3P
I
3P
2E3B/P
Code
3010212

Publicité