Télécharger Imprimer la page

EINHELL TC-AC 200/30/8 OF Instructions D'origine page 17

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
6.3 On/Off switch (8)
To switch on the compressor, press the button (8).
To switch off the compressor, press the button (8)
again (Fig. 1).
6.4 Setting the pressure (Fig. 2)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be drawn from the
quick-lock coupling (5).
6.5 Setting the pressure switch
The pressure switch is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Pull the power plug before doing any
cleaning and maintenance work on the ap-
pliance.
Danger!
Wait until the compressor has completely
cooled down. Risk of burns!
Danger!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
8.1 Cleaning
Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with a
clean cloth or blow it with compressed air at
low pressure.
We recommend that you clean the appliance
immediately after you use it.
Clean the appliance regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be
aggressive to the plastic parts in the appli-
Anl_TC_AC_200_30_8_OF_SPK9.indb 17
Anl_TC_AC_200_30_8_OF_SPK9.indb 17
GB
ance. Ensure that no water can get into the
interior of the appliance.
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
8.2 Condensed water (Fig. 6)
Important! To ensure a long service life of the
pressure vessel (2), drain off the condensed
water by opening the drain valve (1) each time
after using. To open you must turn the cock on the
drain screw through 90°. Tilt the vessel so that the
drain screw is the lowest point of the vessel and
the condensed water can drain off completely.
To close again, turn the cock back through 90°.
Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure
vessel. If you discover any damage, please con-
tact the customer service workshop.
8.3 Safety valve (11)
The safety valve has been set for the highest per-
mitted pressure of the pressure vessel. It is prohi-
bited to adjust the safety valve or remove its seal.
Actuate the safety valve from time to time to en-
sure that it works when required. Pull the ring with
suffi cient force until you can hear the compressed
air being released. Then release the ring again.
8.4 Storage
Danger!
Pull the mains plug out of the socket and ventilate
the appliance and all connected pneumatic tools.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Caution!
Store the compressor only in a dry location
which is not accessible to unauthorized per-
sons. Always store upright, never tilted!
8.5 Carbon brushes
In case of excessive sparking, have the carbon
brushes checked only by a qualifi ed electrician.
Important! The carbon brushes should not be rep
laced by anyone but a qualifi ed electrician.
- 17 -
12.03.2018 08:26:34
12.03.2018 08:26:34

Publicité

loading

Ce manuel est également adapté pour:

40.103.94