POSSIBLE TROUBLESHOOTING
6) Signalling: AL 06 broken or disconnected thermocouple
Problem:
Turns off due to thermo coupling failed or disconnected
Actions:
• Check connection of thermo coupling to board: Check function in cold test (DEALER).
7) Signalling: AL 07 over heated fumes (turns off due to exceeding maximum smoke temperature).
Problem:
Switches off because of overheated fumes.
Over heated fumes may depend on: type of pellets, anomalous fume extraction, blocked channel, incorrect
installation, gear motor drift, lack of air vents in the room.
8) Signalling: "Bat. 1"
Problem:
The stove does not stop but the error appears on the display.
Actions:
• The buffer battery of the control board needs changing (DEALER)
9) Signalling: A LC: Activated when anomalous, insuffi cient current absorption is detected on the gear motor.
Actions:
Check functioning (CAT): gear motor - pressure switch - tank thermostat - electrical connections and electronic
board
10) Signalling: A HC: Activated when anomalous, excessive current absorption is detected on the gear motor..
Actions:
Check functioning (CAT): gear motor - Electrical connections and electronic board.
N.B.:
The combustion chambers and smoke ducts connected to the solid-fuel appliances must be cleaned once a year (check if your
country has specifi c legislation covering this).
Failure to regularly check and clean increases the likelihood of a fi re in the chimney pot.
In the case of a fi re in the stove, in the fl ue or in the chimney, proceed as follows:
- Disconnect the power supply
- Use a carbon dioxide (CO
2
- Call the fi re brigade
DO NOT ATTEMPT TO PUT THE FIRE OUT WITH WATER!
After the event, have the appliance checked by an authorised Service Centre and have an authorised technician check the fl ue.
IMPORTANT!!!
) extinguisher
- 40
-