1) INSTALLATION INSTRUCTIONS
2) PRECAUTIONS FOR USE (The product guarantee depends on compliance with these instructions)
INSTALLATION and USE
For products delivered with filters, these must be installed in accordance with the instructions.
Before commissioning any of our valves, it is essential to carefully drain
the pipes that can damage the mechanisms or water passages (PRESTO® heads that can be dismantled from front).
Recommended operating pressure according to NF EN 816: 1 to 5 bars.
CLEANING
The chrome-plated coating of PRESTO® valves must be cleaned only with soapy water.
Abrasive, acid, alkaline or ammonia-based household products are prohibited.
MAINTENANCE
Never lubricate the internal mechanism, particularly the caps and valve seals.
3) Top inlet with stop valve
4) Flow rate (L/min)
5) Flow regulator
6) Bar
7) Top inlet without stop valve
8) Rear inlet with stop valve
9) INSTALLATION
10) Hydraulic Connection
11) Top inlet
11bis) Filter gasket
12) Rear inlet
13) BATTERY connection
14) Commissioning
15) Maintenance
Product delivered with integrated 8 L/min flow regulator, supplied with spare part 6 L/min regulator
16) Spare parts: (see catalogue)
- DL 400 E Touch cartridge
-Set of 20 self-cleaning needles
-Battery
-Valve
-Shower head grid
-6 L, 8 L, 10 L/min regulator
1. Turn off the water inlet or close the stop valve
17) Dismantling the cartridge
18) Reassembly in reverse order
19) Replacing the shower head grid Ref. 90185 (grid only)
−Unscrewing central screw
− Replacement
20) Replacement: Solenoid valve module and Touch push-button
21) Replacing the battery
22) Lithium battery 6V CRP2
23) See the precaution on the explanatory page of the battery connection
24) PROGRAMMING
3 operating parameters can be programmed:
Within 15 seconds after commissioning the parametes can be programmed
a) Flow time – Adjustable from 1 s to 5 min.
Preset to 30 s.
b) Automatic rinse frequency- Adjustable from 0 to 30 days in steps of 1 day.
Preset without mandatory flow.
c) Automatic rinse flow time– Adjustable from 15 s to 5 min in steps of 15 s.
Preset to 30 s.
25) Mini 10 s
26) Programming OK
27) a) Flow time delay
28) Flow programming activation
29) b) Mandatory rinse frequency
30) Programming of the mandatory rinse frequency
31) day
32) c) Mandatory rinse flow time
33) Programming of the mandatory rinse flow time
34) Note: If we enter the programming procedure of each parameter and do not press anything to modify it, the default
value is re-adjusted.
35) In order to avoid errors, verify properly the scale on paper with the indicated dimensions.
36) This document is not contractual; we reserve the right to modify the characteristics of our products without prior notice.
37) PATENTED and REGISTERED MODELS

Publicité

loading