CAUTION
Risk of hazard due to incorrect repairs
Incorrect repairs can expose users to serious hazards and
cause damage to the equipment.
Never attempt to modify or repair the equipment.
Always have repairs to equipment or cables performed
by a specialist or the service centre.
If you suspect that the equipment is damaged (for
example, if it has fallen on the floor), have it checked
by a specialist before you use it again.
12.2
Problem causes and solutions
The following table is intended to help you localise and solve
minor problems.
Possible
Problem
cause
The rechargeable
Charging station
battery pack of the
plug not connected
parent unit does
Dirty contacts
not charge
The rechargeable
battery pack is
defective
Parent unit does
The rechargeable
not switch on
battery pack is not
(display remains
charged
black)
Equipment
defective
The 'ouange' icon
Baby unit not
appears on the
switched on
parent unit display
t of r
The parent unit and
baby unit are too
far apart
The parent unit is
not registered with
the baby unit
The wrong camera
is selected.
The parent unit
The volume setting
does not reproduce
of the parent unit
the sounds picked
may be too low.
up by the baby unit
The microphone
sensitivity of the
baby unit may be
set too low.
Limited range and
The range of the
interference during
equipment
transmission
depends on the
surroundings.
Steel structures
and concrete walls
can impair
transmission.
The equipment
The parent unit and
emits a high-
baby unit are too
pitched whistle
close together
13 Storage and disposal instructions
13.1
Remove the batteries (regular or rechargeable) from the parent
unit and the baby unit.
Store the equipment in a dry location.
13.2
13.3
Solution
Connect plug
Clean the battery
department for information.
terminals and
Dispose of batteries (regular or rechargeable) in an
charging station
environmentally friendly manner in accordance with local
contacts with a soft
regulations.
cloth
14 Technical data
Replace the
battery pack
Frequency
Range
Charge the battery
pack
Video frame rate
Contact customer
Operating temperature
service
Switch on the baby
Parent unit
unit
Display
Rechargeable batteries
Reduce the
distance between
the parent unit and
AC mains adapter
the baby unit
Register the parent
unit with the baby
unit (see "10.15
Registering the
Dimensions
parent unit with the
Weight
baby unit or
register a new
camera."
Baby unit
See "10.16
Image sensor
Selecting the
Lens
camera"
Night vision
Increase the
Batteries
volume setting of
the parent unit
AC mains adapter
Check the VOX
sensitivity and the
volume setting of
the parent unit and
increase if
Dimensions
necessary.
Weight
Avoid obstacles as
much as possible.
15 EC conformity declaration
Tristar hereby declares that this device is in compliance with the
essential requirements and other relevant provisions of Directive
1999/5/EC.
The declaration of conformity can be found at www.tristar.eu
Increase the
distance to at least
2 metres
We recommend that you keep the box and
packing materials so you can use them to
transport the equipment in the future if necessary.
Storage
Waste disposal of package materials
The package materials are environmentally friendly
materials that can be given to your local waste collector
for recycling.
Waste disposal (environmental protection)
Dispose of the equipment in accordance with the
provisions of European Directive 2002/96/EC, Waste
Electrical and Electronic Equipment (WEEE),
regarding discarded electrical and electronic
equipment. Contact your municipal waste disposal
2,4GHz
Outdoors: up to 300 m (Line of
sight)
Indoors: up to 50 m
25 fps
0°C to 40°C
20% to 75% relative humidity
3,5" (8,8 cm) TFT LCD
Included battery pack:
– JH BL-50C
– Li-ion
– 3,7V 1050 mAh
Manufacturer: 5ESP
Model: 5E-AD060080-E
Input: 100~240V AC, 50/60Hz,
0,15A Max
Output: 6 V DC / 800 mA
approx. 137 x 84 x 60 mm
168 g (without rechargeable
batteries)
Colour CMOS
f 2.8mm, F 2.0
6 Infrared LED
4 Alkaline cells (LR03/AAA) (not
included)
Manufacturer: 5ESP
Model: 5E-AD060080-E
Input: 100~240V AC, 50/60Hz,
0,15A Max
Output: 6 V DC / 800 mA
approx. 86 x 100 x 125 mm
164 g (without batteries)
®