II.1. Anchoring material
The table below provides basic recommendations of fastening for different wall types.
Please consult a specialist to determine your wall type and the appropriate fastening.
The specialist will be also able to determine the wind resistance class of the awning
based
on
WALL TYPE
Concrete
Concrete/ C20-C25
Solid brick
Clay brick/MZ
Sand-lime / KS
Perforated brick
Clay brick / HLZ
Sand-lime brick / KSL
Aerated concrete
Gas concrete / BP2
Cavity wall
The installation of the awning must be conducted by a qualified
person.
Install the brackets on the wall using the right anchors.
Consult a specialist to identify the wall type and the carrying
capacity of the installation site alongside with
anchoring required.
The variables motioned above will affect the wind resistance of
the awning.
Make sure that instructions of the manufacturer of the anchoring
material have been respected before installation of the awning.
40 | ENGLISH
the
condition
of
LOCATION
Ceiling
Ceiling / insulated
Wall
Wall / insulated
Wall
Wall / insulated
Wall
Wall / insulated
Wall
Wall / insulated
Wall / insulated
WARNING
the
wall
and
FASTENING
e.g. TOX Anchor bolt S-Fix Pro 1 A4
e.g. TOX Thermo Proof Plus
e.g. TOX Anchor bolt S-Fix Pro 1 A4
e.g. TOX Thermo Proof Plus
e.g. TOX Masonry Set Wallix
e.g. TOX Thermo Proof Plus
e.g. TOX Masonry Set Wallix
e.g. TOX Thermo Proof Plus
e.g. TOX Masonry Set Wallix
e.g. TOX Thermo Proof Plus
e.g. TOX Thermo Proof Plus
Width [cm]x
Projection[cm]
3,6 x 2.5
the type of
the
fastening
used.
Extraction load on
anchoring [kN]
3 x 2.5
4 x 3
10.33
4,2 x 3
4,5 x 3
4,8 x 3
5 x 3
12,68
4,75
5,45
10,8
11,5
12,2