Télécharger Imprimer la page

Aventics HF03 LG Instructions De Montage page 5

Masquer les pouces Voir aussi pour HF03 LG:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
AVENTICS | HF03 LG/HF04/Stand-Alone-System | R499050014–BAL–001–AE | English
Assembling the system on the DIN rail
Always observe the following points:
O During assembly always observe the operating
instructions for the system.
O Mount the system in such a manner that it is not
released from the DIN rail if the clamps are loosened.
O If more than 16 subbases are fitted on the VS, do not
mount the VS on a DIN rail, because the mounting can
become unstable due to vibrations occurring in
operation.
O Ensure that enough free space is left for the electrical
and pneumatic connections so that the permissible
minimum bending radii for the cables and tubes are
adhered to.
O Select a type of fastening that corresponds to the load
(vibrating or oscillating load).
O Ensure that enough free space is left for the electrical
and pneumatic connections so that the permissible
minimum bending radii for the cables and tubes are
adhered to.
O Select a type of fastening that corresponds to the load
(vibrating or oscillating load).
To mount a system on a DIN rail
1
Observe
:
1. Place the clamps on the system and fasten them with
half a rotation of the screws.
– VS and Stand-Alone system CMS B-design:
2x M6x65 (1a, 1c) (The M6x8 screw and washer
from the delivery contents are not required.).
– Stand-Alone system BDC B-design:
1x M6x65 and 1x M6x8 with washer (1b) (The M6x65
screw from the delivery contents is not required.).
2. Suspend the upper side of the clamps in the DIN rail
and tilt the system down until the clamps engage (2).
3. Tighten the screws to fix the clamps (tightening torque:
3,5 + 0.5 Nm) (3).
Disassembling the system from
the DIN rail
Loosened mounting screws on the system
The system may come loose and be damaged if the
hexagon socket screws used for mounting the DIN rail
are completely unscrewed during disassembly.
O For disassembly, unscrew the mounting screws by
no more than 2 rotations.
2
Observe
:
1. Make sure the system is not under pressure or voltage
before disassembly.
2. Loosen all connections on the system.
3. Loosen both of the hexagon socket screws (4).
4. Tilt the system upwards until the clamps disengage
and carefully lift it towards the front (5).
5
Disposal
Dispose of the packaging and used parts in accordance
with the regulations of the country in which the mounting
kit is used.
CAUTION
4

Publicité

loading

Ce manuel est également adapté pour:

Hf04