Terminals
Earth
Connects to the Earth
Output
Connects to the Fence
Battery Protection Features
Ba ery Save
•
12V ba eries typically have their life permanently reduced if they are
over-discharged. Your PowerPlus energizer includes several automa c ba ery
protec on features to reduce damage from over discharge of the ba ery.
•
The energizer pulse rate will automa cally slow to half pulse rate if the ba ery
voltage falls to less than 12V, to conserve power.
•
The energizer will automa cally switch off if the ba ery voltage falls to less than 11V
to protect the ba ery from permanent damage. The energizer will turn on again
automa cally if the ba ery voltage increases again, (e.g. if a solar panel is connected
and starts recharging the ba ery). This switch-off feature can be disabled if required,
contact your dealer for this modifi ca on.
Battery Performance
Ba ery Life
Energizer
B80
B180
B280
Note:
Ba ery life is based on a fully charged 60Ah ba ery.
Over Voltage Warning
The bar graph will display by fl ashing all LEDs on and off con nuously, on any
switch se ngs, if the ba ery input voltage exceeds 18V. The energizer will
automa cally shut down to prevent opera on at voltages that could cause
damage.
10
Gallagher 3E0917 B80 B180 B280 Portable Fence Energizer
Normal
(Weeks)
4.5
2.3
1.4
Night Save
(Weeks)
N/A
3.5
2.1
Random Pulse
(Weeks)
N/A
7.2
4.2