Télécharger Imprimer la page

Refsta PURO INSELHAUBE Notice D'utilisation page 20

Masquer les pouces Voir aussi pour PURO INSELHAUBE:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
purification module Y figure 3 -phase 6 and secure the flange
with the screw C1 figure 3- phase 7.
- Take the fitting E and position it at the air outlet hole E1 figure
3 - phase 8.
- Fix the purification module Y above the motor unit using the
4 screws F as indicated in figure 3 - phase 10 - 11.
- Remove the structure from the packaging and remove the 2
screws A to separate the upper part from the lower part figure
4 - phase 12.
Separate the upper bracket H from the structure B as indicated
in figure 5 - phase 13 and replace it with bracket H1 figure
5 - phase 14 - 15.
- Position the perforation template on the ceiling making
sure the arrow is positioned on the same side as the appli-
ance control (Fig.6).
- Drill 4 Ø8 holes in the ceiling and tighten the 3 screws with-
out pulling them completely making sure not to insert the
screw in the hole marked with an X on the perforation tem-
plate fig.7 (the screws and expansion plugs must be suited
for the type of wall).
- Take the hood and insert the upper telescopic structure on
the 3 screws E not tightened completely corresponding to
the 3 slots and turn them slightly to fit them as indicated in
figure 8 - phase 1-2.
Tighten the fourth screw X and pull the other 3 to perma-
nently block the upper part of the structure B as indicated in
figure 8 - phase 3-4.
- Take the lower part of the telescopic structure C and insert it
into the upper structure B (Fig.9). Adjust the height by referring
to the amounts indicated in (Fig.10) and block it using the 8
screws G that are supplied (Fig.10).
- Take the upper chimney piece and fix it to the structure using
the 2 screws A (Fig.11).
- Join the lower chimney piece with the upper one and fix it
carefully using adhesive tape L figure 12 - phase 1.
- Unscrew the 2 screws O, max 3 mm figure 12 - phase 2. Insert
the suction unit inside the structure paying attention that the
previously unscrewed screws O, hook into the slots in the lower
part as indicated in figure 12 - phase 3. Drive in the 3 screws
N (supplied) and tighten the 2 screws O figure 12 - phase 4-5.
- Remove adhesive tape L and rest the lower chimney piece
above the cooker hood (Fig.13).
- When carrying out the fixing operations, use only screws
and screw anchors suited to the type of wall (e.g. reinforced
concrete, plasterboard etc.).
- If the screws and screw anchors are supplied with the ap-
pliance, make sure that they are suited to the type of wall to
which the hood must be fixed.
USE AND MAINTENANCE
• We recommend that the cooker hood is switched on before
any food is cooked. We also recommend that the appliance is
left running for 15 minutes after the food is cooked, in order
to thoroughly eliminate all contaminated air. The effective
performance of the cooker hood depends on constant main-
tenance; the anti-grease filter.
• The anti-grease filter is responsible retaining the grease
particles suspended in the air, therefore it is subject to clogging
with variable frequency according to the use of the appliance.
- To prevent the danger of possible fires, at least every 2
months one must wash the anti-grease filters by hand using
non-abrasive neutral liquid detergents or in the dishwasher
at low temperatures and on short cycles.
- After a few washes, colour alterations may occur. This does
not give the right to claim their replacement.
• Clean the hood frequently, both internally and externally,
using a cloth dampened with denatured alcohol or neutral
liquid detergents that are non abrasive.
• The lighting .system is designed for use during cooking
and not for the prolonged general lighting of the room. The
prolonged use of the lighting system significantly decreases
the average duration of the bulbs.
• If the appliance is equipped with courtesy lights it is possible
to use them for general room lighting for a prolonged amount
of time.
• Attention: the non compliance with the hood cleaning
warnings and with the replacement and cleaning of the filters
entails risk of fires. One therefore recommends keeping to the
suggested instructions.
• Replacing LED lamps (Fig.9):
If the appliance version is with LED lamps, the intervention of
a specialised technician is necessary to replace them.
• Commands luminous (Fig.10) the key symbols are explai-
ned below:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes (*)
If your appliance has the INTENSIVE speed function, from
speed THREE, press key E for 2 seconds and it will be activa-
ted for 6 minutes after which it will return to the previously
set speed. When the function is active the LED flashes. To
interrupt it before the 6 minutes have elapsed, press key E
again. Some models allow activating this function even with
speed one and two.
By pressing key F for two seconds (with the hood switched off)
the "clean air" function is activated. This function switches the
appliance on for ten minutes every hour at the first speed. As
soon as this function is activated the motor starts up at the
first speed for ten minutes. During this time key F and key
C must flash at the same time. After ten minutes the motor
switches off and the LED of key F remains switched on with
a fixed light until the motor starts up again at the first speed
after fifty minutes and keys F and C start to flash again for ten
minutes and so on. By pressing any key for the exclusion of
the hood light the hood will return immediately to its normal
functioning (e.g. if key D is pressed the "clean air" function is
deactivated and the motor moves to the 2nd speed straight
away. By pressing key B the function is deactivated).
(*) The "AUTOMATIC STOP TIMER" delays stopping of the
hood, which will continue functioning for 15 minutes at the
operating speed set at the time this function is activated.
• Anti-grease/active charcoal filters saturation:
- When the A key flashes with a 2 second frequency the anti-
grease filters must be washed.
Once the clean filter has been put back one must reset the
electronic memory by pressing the A key for approximately 5
seconds until it stops flashing.
- When the key A flashes with a 0.5 seconds frequency, nothing
needs to be replaced as this hood is equipped with an inde-
pendent air purification system. You must reset the electronic
memory by pressing the key A for approximately 5 seconds
until it quits flashing.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR EVENTUAL DAMAGES CAUSED BY BREACHING THE
ABOVE WARNINGS.
- 20 -

Publicité

loading

Ce manuel est également adapté pour:

Puro inselhaube plus