INTRODUCTION
DESCRIPTION
Your new plasma arc cutter has been designed to cut any electrically conductive material in
applications such as maintenance shops, service stations, van conversion shops, auto restoration and
salvage operations, etc.
On steel, all models can cut thicknesses of less than 26 gauge but the 120V model can cut up to 5/16"
inch steel, and the 230V model can cut up to 3/8" inch steel.
Your plasma arc cutter comes complete and ready to cut. All you need to provide is a clean, dry, oil
free compressed air supply.
The system is based on a modern DC inverter power supply. This special technology allows for the
construction of compact lightweight unit with high performance. Infinite power adjustment, high
efficiency and reduced power consumption make it an excellent tool.
SPECIFICATIONS
Input Voltage
Input Amps @
Rated Output
Input Plug Style
Power Cord Length
Rated Output Amps
Max Output Amps
Rated Output Volts
Rated Duty Cycle
Max Open Circuit
Voltage
Agency Listing
Output Settings
Air Requirement
ASSEMBLY
UNPACKING YOUR PLASMA CUTTER
1. Remove the unit from the carton. .
2. Remove any cartons or bags containing accessories.
3. Open the cartons or bags packed with your unit and inspect their contents for damage.
4. Lay out the parts and compare them to any illustrations in this manual to familiarize yourself
with them and what they are called. This will help you when reading the manual.
POWER REQUIREMENTS
This Plasma Cutter is designed to operate on a properly grounded power source fused with a
minimum 20 amp fuse or circuit breaker. If you modify the power cord in any way, you will void the
manufacturer's warranty. It is recommended that a qualified electrician verify the actual voltage at the
receptacle into which the welder will be plugged and confirm that the receptacle is properly fused and
grounded. The use of the proper circuit size can eliminate nuisance circuit breaker tripping while
welding.
DO NOT OPERATE THIS UNIT if the actual power source voltage is less than 100 volts AC or greater
than 125 volts AC (120) volt models); less than 198 volts AC or greater than 240 volts AC (230 volt
models). Contact a qualified electrician if this problem exists. Improper performance and/or damage to
the welder will result if operated on inadequate or excessive power.
120 VOLT MODELS
120 volt 60 Hz. Single
Phase
20 AAC
120 volt 15 amp
10 ft.
20 ADC
25 ADC
90 VDC
35%
195 VDC
CSA
Infinite
3.5 cf – 100l/min @ 55psi
230 VOLT MODELS
230 volt 60 Hz. Single
Phase
20 AAC
230 volt 50 amp
10-ft.
30 ADC
30 ADC
90 VDC
35%
195 VDC
CSA
Infinite
3.5 cf – 100l/min @ 55psi
13