Settings with the HyTronic Service-Handy
Commands
Menu item
Description
[EN]
[DE]
20
Release flush.
[Flush]
Releases a flush
[Spülung]
21
Block flush.
[BlocFlush]
No flush is released.
[Blockiere]
The function switches off
automatically after 10 h
22
Empty pipe.
[EmptyPipe]
The valve is opened so that the
[RohrLeer]
pipe can be drained.
The function switches off
automatically after 30 min
23
Factory settings.
[FactrySet]
All functions are reset to the
[Werkseinst]
factory setting
24
Switch cleaning mode.
[CleanMode]
Flush control is inactive for the
[Reinigung]
duration of the entered
value 44 [CleanTime] [ReiniZeit].
Flushes at the end of this period
The functions described here may only be set by a skilled person.
The functions which are described here for hidden urinal control can be set
individually using the HyTronic Service-Handy. The numbers and terms in the
column "Menu item" correspond to what can be seen on the display of the
HyTronic Service-Handy. Further information can be found in the operating
instructions of the HyTronic Service-Handy.
There is no connection to the flush control during a flush and for up to 6 s
afterwards. The HyTronic Service Handy cannot process any commands during
this time.
Application
a) Function test for the valve
b) Flushing of the urinal ceramic
(e.g. when setting the optimum
flush volume)
a) In the case of detection
malfunctions
b) Environment has changed
For repair works and
maintenance work
In the case of malfunctions
Cleaning the urinal ceramic
without flushing
Service
Adjustment
Factory
range
settings
Start = "OK"
–
On = "OK"
–
Off = "OK"
On = "OK"
–
Off = "OK"
Start = "OK"
–
Start = "OK"
–