OBJ_BUCH-828-006.book Page 16 Friday, July 1, 2016 12:52 PM
16 | English
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the
measuring tool.
To open the battery lid 6, press on the latch 7 and fold the
battery lid up. Insert the batteries. When inserting, pay at-
tention to the correct polarity according to the represen-
tation on the inside of the battery compartment.
When the battery indication 8 flashes, the batteries are
weak. When the battery indication flashes for the first
time, the measuring tool can still be operated for approx.
2 h.
When the battery indication 8 lights up constantly, mea-
suring is no longer possible. The measuring tool automat-
ically switches off after a short time.
Always replace all batteries at the same time. Only use
batteries from one brand and with the identical capacity.
Remove the batteries from the measuring tool
when not using it for extended periods. When stor-
ing for extended periods, the batteries can corrode
and self-discharge.
Operation
Initial Operation
Protect the measuring tool against moisture and di-
rect sun light.
Do not subject the measuring tool to extreme tem-
peratures or variations in temperature. As an exam-
ple, do not leave it in vehicles for a long time. In case of
large variations in temperature, allow the measuring
tool to adjust to the ambient temperature before put-
ting it into operation. In case of extreme temperatures
or variations in temperature, the accuracy of the mea-
suring tool can be impaired.
Avoid heavy impact to or falling down of the mea-
suring tool. Damage to the measuring tool can impair
its accuracy. After heavy impact or shock, compare the
laser lines or plumb beams with a known horizontal or
vertical reference line or with already checked plumb
points.
1 609 92A 1Z2 | (1.7.16)
Switching On and Off
To switch on the measuring tool, press the On/Off button
3 once briefly. Immediately after the switching on, the
measuring tool projects the three laser lines 0°, 45° and
90° from the exit openings 1. Furthermore, the battery in-
dication 8 lights up for 3 s.
Do not point the laser beam at persons or animals
and do not look into the laser beam yourself, not
even from a large distance.
When the On/Off button 3 is pressed a second time, the
measuring tool switches over from 3-line operation to
2-line operation: Only the 0° and the 90° laser lines are
projected.
To switch off the measuring tool, press the On/Off button
3 a third time.
Deactivating the Automatic Shut-off
The measuring tool switches off automatically after an op-
erating duration of 30 minutes.
To deactivate the automatic switch-off, press the On/Off
button 3 for 3 s when you switch on the measuring tool.
When the automatic switch-off is deactivated, the laser
lines flash briefly to confirm after the switching on.
Do not leave the switched-on measuring tool unat-
tended and switch the measuring tool off after use.
Other persons could be blinded by the laser beam.
To activate the automatic switch-off, switch the measur-
ing tool off and switch it on again by pressing briefly the
On/Off button 3. After the switching on, the laser lines do
not flash.
Angular accuracy
Influences on Accuracy
The ambient temperature has the greatest influence. Es-
pecially temperature differences occurring from the
ground upward can divert the laser beam.
Therefore, position the measuring tool as near as possible
to the work surface and fix it with the underside as parallel
as possible to the work surface.
In addition to external influences, device-specific influ-
ences (e.g. falls or heavy impacts) can also lead to devia-
tions. For this reason, check the levelling accuracy each
time before beginning work.
Bosch Power Tools