Determine And Set Wiring Type - LiftMaster Elite Série Manuel D'installation

Masquer les pouces Voir aussi pour Elite Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DETERMINE AND SET WIRING TYPE

Read the descriptions of the different wiring types to determine which setting will be correct for each application. Once the wiring type is
determined, set the selector dial accordingly.
WIRING TYPE
DEVICE
3-Button
Control Station
C2
Momentary contact
to open and stop
with constant
pressure to close,
open override plus
wiring for sensing
device to reverse.
Programmable
Mid-Stop available
with this wiring-
type. Compatible
3-Button
with 3-Button
Remote Control
Station and
Programmed as
1-Button Station
OPEN/CLOSE/STOP
Single Button
Remote Control
Single Button
Control Station
(Wired)
MyQ
Programming
ACTION
STATE
Operator at OPEN limit
Operator at CLOSE limit
OPEN button is pressed
Door opening
momentarily:
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
CLOSE button is
pressed momentarily:
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
STOP button is pressed
Door opening
momentarily:
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
OPEN button is held
(constant pressure):
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
CLOSE button is held
Door opening
(constant pressure):
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
OPEN button is pressed
momentarily:
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
CLOSE button is
Door opening
pressed
Door closing
momentarily:
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
STOP button is pressed
momentarily:
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Button is pressed
momentarily:
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Button is pressed:
Door closing
Door at Open Mid-Stop
Door stopped during open cycle
Door stopped during close cycle
Operator at OPEN limit
Operator at CLOSE limit
Door opening
Door image is pressed:
Door closing
Door at Open Mid-Stop
Door stopped during open or close cycle
RESPONSE
No change in state
Door opens to closest OPEN limit or Mid-Stop
No change in state
Door will auto reverse to OPEN limit
Door opens to the OPEN limit
Door opens to closest OPEN limit or Mid-Stop
Door closes and stops when button is released
No change in state
No change in state
No change in state
Door closes and stops when button is released
Door closes and stops when button is released
No change in state
No change in state
Door stops
Door stops
No change in state
No change in state
No change in state
Door opens to closest OPEN limit or Mid-Stop
No change in state
Door will auto reverse to OPEN limit
Door opens to the OPEN limit
Door opens to the OPEN limit (bypasses Mid-Stop)
Door closes to closest CLOSE limit or Mid-Stop
No change in state
No change in state
No change in state
Door closes to the CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
No change in state
Door opens to closest OPEN limit or Mid-Stop
No change in state
Door will auto reverse to OPEN limit
Door opens to the OPEN limit
Door opens to closest OPEN limit or Mid-Stop
Door closes to closest CLOSE limit or Mid-Stop
No change in state
No change in state
No change in state
Door closes to the CLOSE limit
Door closes and stops when button is released
No change in state
No change in state
Door stops
Door stops
No change in state
No change in state
Door closes and stops when button is released
Door opens to closest OPEN limit or Mid-Stop
Door stops
No change in state
Door opens to the OPEN limit
Door opens to the OPEN limit
Door closes and stops when button is released
Door opens to closest OPEN limit or Mid-Stop
Door Stops
Door will auto reverse to OPEN limit
Door opens to the OPEN limit
Door closes and stops when button is released
Door opens to closest OPEN limit or Mid-Stop
Door closes to the CLOSE limit
Door opens to closest OPEN limit or Mid-Stop
No change in state
No change in state
Door closes to the CLOSE limit
Door closes to the CLOSE limit
28