Mitsubishi Electric ecodan EHSC Série Manuel D'installation page 18

Masquer les pouces Voir aussi pour ecodan EHSC Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 66
4
Installation
Hydrobox powered via outdoor unit
(If you want to use independent source, go to the Mitsubishi website.)
<1 phase>
Affix label A that is included with the manuals near each wiring diagram for hydrobox and outdoor units.
Power supply
~/N 230 V 50 Hz
en
<3 phase>
Affix label A that is included with the manuals near each wiring diagram for hydrobox and outdoor units.
Power supply
3N~ 400 V 50 Hz
Hydrobox - Outdoor unit
Wiring No.
× size (mm²)
Hydrobox - Outdoor unit earth
Hydrobox - Outdoor unit S1 - S2
Circuit rating
Hydrobox - Outdoor unit S2 - S3
*1. If the installed earth leakage circuit breaker does not have an over-current protection function, install a breaker with that function along the same power line.
*2. A breaker with at least 3.0 mm contact separation in each pole shall be provided. Use earth leakage breaker (NV).
The breaker shall be provided to ensure disconnection of all active phase conductors of the supply.
*3. Max. 45 m
If 2.5 mm² used, Max. 50 m
If 2.5 mm² used and S3 separated, Max. 80 m
*4. The values given in the table above are not always measured against the ground value.
Notes:
1. Wiring size must comply with the applicable local and national codes.
2. Indoor unit/outdoor unit connecting cords shall not be lighter than polychloroprene sheathed flexible cord. (Design 60245 IEC 57)
Indoor unit power supply cords shall not be lighter than polychloroprene sheathed flexible cord. (Design 60227 IEC 53)
3. Install an earth longer than other cables.
4. Please keep enough output capacity of power supply for each heater. Insufficient power supply capacity might cause chattering.
17
Earth
Wiring
leakage
circuit
circuit
breaker or
breaker
Isolating
switch
*1, *2
Power supply
~/N 230 V 50 Hz
<Figure 4.4.2>
Electrical connections 1 phase
Description
Power supply
Booster heater
~/N 230 V 50 Hz
Earth
Wiring
leakage
circuit
circuit
breaker or
breaker
Isolating
switch
*1, *2
Power supply
3~ 400 V 50 Hz (EH**-YM9*D)
3~ 230 V 50 Hz (EH**-TM9*D)
<Figure 4.4.3>
Electrical connections 3 phase
Description
Power supply
3~ 400 V 50 Hz
Booster heater
3~ 230 V 50 Hz
*3
3 × 1.5 (polar)
*3
*4
*4
Outdoor unit
L
S1
N
S2
S3
Wiring
circuit
breaker or
Isolating
switch
Capacity
Breaker
Wiring
2 kW
16 A *2
2.5 mm²
6 kW
32 A *2
6.0 mm²
Outdoor unit
L1
S1
L2
S2
L3
S3
N
Wiring
circuit
breaker or
Isolating
switch
Capacity
Breaker
Wiring
9 kW
16 A *2
9 kW
32 A *2
1 × Min. 1.5
230 V AC
24 V DC
Hydrobox
TB1
L
N
To control
board
S1
S2
S3
ECB1
For
L
booster
heater
N
Hydrobox
TB1
L
N
To control
board
S1
S2
S3
ECB1
L1
For
L2
booster
heater
L3
2.5 mm²
6.0 mm²

Publicité

Table des Matières
loading

Table des Matières