Dometic FreshWell 2000
5.4
Air conditioning modes
The under-bench air conditioner has the following air conditioning modes:
Air condition-
ing mode
Automatic
Cooling
Dehumidification
Circulating air
EN
Display
Explanation
message
You specify the blower settings, and the under-
bench air conditioner controls the necessary
operation mode.
The under-bench air conditioner measures the
interior temperature and sets the temperature as
follows:
– interior temperature ≤ 20 °C: 20 °C
(operation mode: circulating air)
– 20 °C < interior temperature < 25 °C: 22 °C
(operation mode: dehumidification or circulat-
ing air)
– interior temperature ≥ 25 °C: 25 °C
(operation mode: cooling)
The + and – buttons are deactivated in this
mode.
You specify the temperature and blower settings,
and the under-bench air conditioner cools the
interior to this temperature.
You specify the temperature, and the under-
bench air conditioner cools the interior to this
temperature and controls the necessary blower
output and dehumidifies the interior (circulating
air mode).
The FAN SPEED button is deactivated in this
mode.
You specify the temperature and the blower level,
and the under-bench air conditioner blows cold
air (cooled circulating air) into the interior.
Technical description