Never pull the trigger more than once at time with the tip in
the reverse position.
Attention
c. Continue this procedure until the tip is clear of the clog.
Changing a Tip
Tips can be removed and replaced easily without disassembling the gun.
Identifying Tip Sizes
To identify tip sizes, use the following formula. A "517" tip size will be used in
this example.
The first digit multiplied by two represents the size of the spray pattern when
spraying 12" away from the work surface:
5 x 2 = 10" spray pattern
The second two digits represent the diameter of the orifice on the tip:
17 = .017" orifice
Never attempt to change or clean the tip or tip guard without
first performing the "Pressure Relief Procedure."
1. Perform the "Pressure Relief Procedure" described in the sprayer's
Owner's Manual.
2. Remove the tip from the slot on the tip guard.
3. Insert the new tip into the slot on the tip guard. The arrow on the tip
handle should be pointing in the forward direction for spraying.
Removing the Seal and Tip seal
1. Remove the tip and tip guard from the spray gun.
2. Remove the seal and tip seal from the back of the tip guard.
Worn tips have a negative impact on the spray pattern and will
i
lead to increased material consumption and a smaller width of
the spray jet. Replace worn tips immediately.
8