Électrocompresseur à pistons avec silencieux

Publicité

Les langues disponibles
  • FR

Les langues disponibles

GB
Thermostat -The fan condenser is activated when the condensate temperature reaches or exceeds 35°C (FANON) - LED
- and it is deactivated when the temperature goes down to 30°C (FANON - Hys) - LED
fun will run continuously and the LED
Timer -The condensate drain solenoid valve is activated for 2 seconds (TON) - LED
setting.
To perform the manual test for the condensate drain, press the button
SET-UP - The DMC15 is adjusted during the final test of the dryer. In case of particular requirements concerning the operation
management,the user can change the setting of the programmed parameters. The parameters which can be set up are the
following:
-FANON - activation temperature of condenser fan. It is adjustable inside the following range of values, with step of 1°K; whereas
the Hys hysteresis is fixed and equal to -5ºK.
-T ON - activation time of the condensate drain solenoid valve.
-TOFF - pause time between two consecutive activation of the condensate drain solenoid valve.
To access the set-up, keep the button
appears the (FANON) parameter; to access the other parameters, press sequentially the
the selected parameter, keep the
display. For the value range and the resolution (value of each single LED), see the following table:
Description
Parameter
Activation temperature of the
FAN
ON
condenser fan
Activation time of the
T
ON
ondensed drain solenoid valve
Pause time of the condensate
T
OFF
drain solenoid valve
To exit the set-up condition in any moment, press the
automatically exits the set-up condition.
will intermittent flash.
pressed for at least 2 seconds; LED
button pressed and operate on
Visualizzazione
Synchronous flashing
LED
+ LED
Synchronous flashing
LED
+ LED
Non-synchronous flashing
LED
+ LED
button . If no operations are performed for 2 minutes, the system
18
off. In case of (T2) probe failure, the
on - each minute (TOFF), if standard
flashing confirms the command. First
button. To change the value of
button ; the current value is shown on the LED
Resolution
Value
range
31 - 40 °C
1 - 10 sec
1 - 10 min
on
Set value
1°K
35°C
1 sec
2 sec
1 min
1 min

Publicité