Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operation mode selection
J2
Potentiometer adjustment
T.E.
6

STARTING UP

Final checks
Following installation and programming, start up the
shutter gate and check all the devices installed:
• key commands (transmitter, push button and wall
key)
• safety devices (photocells or mechanical strips)
If the system does not work correctly, find out
why and put it right (see section "Failure
diagnosis" on page 28).
Place J2 in the required position:
Step-by-step mode (J2=SEMI)
– Opening is done by briefly running the key
SEMI
device.
– Closing is done by briefly running the key device.
Automatic mode (J2= AUTO)
– Opening is done by briefly running the key
device.
AUTO
– Closing is carried out automatically when
standby time finishes, which can be set using the
T.E. power meter
P166L
Open shutter gate standby time (T.E.) adjustment
If automatic operation mode has been programmed,
adjust T.E. to set standby time with the shutter gate
open (before automatic closing begins).
Minimum value: 5 seconds;
T.M.
maximum value: 140 seconds
Duration of the operations (T.M.)
The duration of the opening and closing operations is
adjusted using T.M.
1 Adjust the FCC and FCA limit switches of the
operator.
2 Adjust T.M. to ensure the shutter gate completes
the runs (it must reach the FCC and FCA limit
switches of the operator).
P166M
Minimum value: 1 second;
maximum value: 70 seconds
User instruction
1 Instruct the user with regards to the use and
maintenance of the installation and provide him/her
with the user guide.
2 Signpost the shutter gate, showing that it opens
automatically and indicating how to operate it
manually.
operation is using the radio transmitter.
INSTALLING AND PROGRAMMING
Where
appropriate,
indicate
CLEVER01 Control panel
that
27

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Clever01m

Table des Matières