INSTALLING AND PROGRAMMING
Connection of safety transmitter-receiver photocells in closing (SG.C, FT1)
(2) GND
(3) FT1
5

PROGRAMMING

Radio code programming
When using the ERREKA RSD plug-in receiver
(decoder-free receiver, trinary code, 433Mhz),
the radio code can be recorded in the control
board itself, as explained below. In other cases,
follow the instructions of the plug-in receiver
used.
26
Installation Manual
1 2 3 4 5
10
9
8
L4
SW1
RSD
We recommend installing safety photocells.
1 Complete the connections as shown in the figure.
7
O
If neither photocells nor a mechanical strip are
connected, make an electrical bridge between cable
connectors (2) GND and (3) FT1.
P166I
1 Connect the control panel power supply (S1 in
ON).
2 Briefly press mini-pushbutton SW1. LED L4
flashes.
3 Press the transmitter button to be programmed.
The L4 LED flashes to show that the code has
been correctly programmed.