Cabinet Installation
The hood can be installed under a cabinet by supporting
the hood from the top.
Note:
The cabinet must be structurally joined to the wall studs to
support the weight of this hood.
Figure 14 shows the (4) screw holes labeled "K" used for
mounting the hood to the bottom of the cabinet. Make sure
both knockouts have been removed.
Tap Hole Locations
A
23"
(584mm)
L
K
Note:
This figure
depicts tap hole
and screw hole locations only. See
Figure 1 on page 1, for overall
hood dimensions.
Figure 14: Tap Hole and Screw Hole Locations
1. In the base of the cabinet, drill 1/8" (3mm) tap holes
(Dimension A in Figure 14 and in Table 2,). Screw in
(4) 1" (25mm) screws (provided with hood) leaving 1/4"
(6mm) exposed to hang hood on.
2. If the hood is installed for vertical discharge, use
Figure 14 to create clearance holes for passage of the
transition and conduit (see Dimension B in Figure 8
and in Table 2 on the current page).
3. For horizontal discharge, use Figure 9 on page 8 for
the geometry of the cutout required for clearance of the
transition.
4. Hang hood from screws and tighten securely.
5. From inside of hood, insert screws supplied. Drill
through holes, use 5/8" (16mm) screws supplied, (1) on
each side and (4) along the front, into bottom of the
cabinet. See screw holes labeled "L" in Figure 14.
English 10
HOOD
SIZE
30" (762mm)
36" (914mm)
42" (1067mm)
48" (1219mm)
54" (1372mm)
Table 2: Centerline Hole Dimensions for Figure 14 & Figure 8
9
K
1
/
"
Blower Installation
16
(40mm)
1
7
/
"
16
All hoods require the choice of a Remote (Figure 20 on
(17mm)
page 13), Integral (Figure 18 on page 12), or Inline Blower
L
(Figure 22 on page 14). Use only THERMADOR
with THERMADOR
are sold separately. See page 1 for recommended blowers
and for max current ratings.
1. The blower is attached to the hood using weld studs
L
2. Figure 15 shows the weld studs in location B for
3. Guide the motor mounting plate over the studs and
A (Fig 13)
Tap Holes
29" (736mm)
35" (889mm)
41" (1041mm)
47" (1194mm)
53" (1346mm)
®
ventilation hoods. All blower models
provided on the mounting plate.
horizontal (rear) discharge. Attach (4) nuts (included
with hood) to the weld studs. For vertical discharge,
attach nuts to studs at the top of the mounting plate.
tighten nuts to secure the blower to the hood.
B
Figure 15: Weld Stud Locations
B (Fig 7)
Conduit Holes
13" (330mm)
16" (406mm)
19" (483mm)
22" (559mm)
25" (635mm)
®
blowers
B