EN
58
Technical specifications
Technical specifications
Dimensions
Length
Width
Height
Environmental conditions – Relative humidity
Protection rating
Operating temperature
Electrical data
Rated operating voltage
Maximum current consumption at 24 V DC
Relay contact loading capacity (ohmic load)
With fire alarm system connected to input
12 V DC
B
("Inputs", page 40)
107 mm (6TE)
90 mm
65.5 mm
0 to 95 %
Non-condensing
IP30
–10°C – +55°C
12 V / 24 V DC (regulated)
Note:
Please observe the techni-
cal data of the lock in
question!
115 mA
185 mA
30 V / 1 A
12 V DC – 24 V DC
Technical specifications