Acceptance test (in case of industrial/public use):
Before first use and after any significant modifications, the installation (including the electrical
connections) must be inspected by an official expert.
A yearly inspection by an expert is required.
At least every 4 years, an acceptance test must be carried out by an expert.
• Set up the fog machine under observation of the above safety notes.
• The fog machine can also be suspended with the enclosed U-shaped mounting bracket. Always observe
horizontal installation for this. Use the enclosed longer screws for attaching the mounting bracket.
• The laser unit can be directly connected to the fog machine with the enclosed mounting bracket. This
permits best alignment for the best effect in connection with the fog emission of the fog machine. Pro-
ceed as shown in the following figures for assembly of the fog machine.
• Attach the bent mounting bracket to the bottom of the fog machine as shown with one of the short enclo-
sed screws.
• Attach the laser unit to the mounting bracket with the second short screw as shown.
29