2.4.5.3.
COM2 with Discrete I/O Connections
The COM2/Discrete I/O option board (Figure 2-61) is positioned in option position 1 on the main
board, and provides the COM2 serial port with two isolated inputs and four dry-contact normally
open relay outputs. The inputs can be selected as either active or passive based on the position of
the slide switch on the board.
2.4.5.3.1.
COM2
The COM2 port on the COM2/DIO option has the same connection as described in the previous
COM2 section. Refer to that section for details.
64084463
|
02
|
12/2013
NOTES
USE ONLY SHIELDED CABLE
MAXIMUM CABLE LENGTH: 50 FEET (15 METERS)
WIRE SIZE: 18 AWG (0.832 mm
NOTES
USE ONLY SHIELDED CABLE
MAXIMUM CABLE LENGTH: 1000 FEET (304 METERS)
WIRE SIZE: 18 AWG (0.832 mm
Figure 2-60: Sample COM2 Connections
Figure 2-61: COM2 with Discrete I/O Option Board
METTLER TOLEDO IND246 and IND246 POWERCELL Installation Manual
2
) MAXIMUM
2
24 AWG (0.205 mm
) MINIMUM
2
) MAXIMUM
2
24 AWG (0.205 mm
) MINIMUM
Outputs
Inputs
2-31