5. Attach both ring terminals either to the grounding stud (see Figure 2-54).
6. Insert the black ground wire into the POWERCELL connector on the motherboard and tighten it
7. Remove the connector from the motherboard, to simplify connection of the remaining wires.
8. Twist the blue and white wires together, and cut them and the red wire to the appropriate
9. Insert the wires into the connector as indicated in Table 2-4.
64084463
|
02
|
12/2013
b. Terminate one end with the ring terminal provided.
c. Strip enough of the insulation at the free end of the black wire to permit insertion into the
connector on the motherboard.
Figure 2-53: Black Grounding Wire with Ring Terminal
in place. This establishes the correct orientation of the wires in the connector.
length, to reach the connector at the motherboard without putting strain on the wires or
connections.
Terminal
CANH
- -
CANL
+24V
GND
METTLER TOLEDO IND246 and IND246 POWERCELL Installation Manual
Table 2-4: PDX Cable Color Code
Description
CANbus High
Not Used - Empty
CANbus Low
PDX Network Power Supply
PDX Network Ground
Wire Color
White
- -
Blue
Red
Black
2-27