Description Of Bravo Kit Connection Diagrams; A Second Art. 4876Kc, An Additional Secondary Monitor And; Second Art. 4876Kc, An Additional Main Monitor And An; Connection In Cascade - Comelit Group MT KIT 10 Manuel Technique

Color bravo kit
Table des Matières

Publicité

GROUP S.P.A.

DESCRIPTION OF BRAVO KIT CONNECTION DIAGRAMS

Basic wiring for single-family kits Art. 8184
Diagram BK/01C
Main diagram for single-residence kits Art. 8184.
Refer to the indications on page 36 for the wires to be used and the
maximum operation distances.
Configuration of microswitches (hereinafter DIP) on the bracket:
DIP 1 ON - DIP 2, DIP 3, DIP 4, DIP 5 OFF:
set user code number 1 for call from single-residence external unit
(4875KC).
DIP 6, DIP 7, DIP 8: depending on the required functions.
JP1 in position P: sets the monitor bracket as main.
Refer to the table on page 39 for indications regarding settings of
possible configurations.
Basic wiring for two-family kits Art. 8185
Diagram BK/02BC
Branch connection
Main diagram for two-residence kits Art. 8185.
Refer to the indications on page 36 for the wires to be used and the
maximum operation distances.
Configuration of microswitches (hereinafter DIP) on the bracket:
DIP 1 ON - DIP 2, DIP 3, DIP 4, DIP 5 OFF:
set user code number 1 for call from two-residence external unit
(4876KC).
DIP 2 ON - DIP 1, DIP 3, DIP 4, DIP 5 OFF:
set user code number 2 for call from two-residence external unit
(4876KC).
DIP 6, DIP 7, DIP 8: depending on the required functions.
JP1 in position P: sets the monitor bracket as main.
Refer to the table on page 39 for indications regarding settings of
possible configurations. End the riser with terminal Art. 1216 as
shown in the diagram.
The max. distance between Art. 1214KC and the monitor is 20 m.
Diagram BK/02AC

Connection in cascade

Main diagram for two-residence kits Art. 8185.
Refer to the indications provided on page 36 for the wires to be
used and the maximum operation distances.
Configuration of microswitches (hereinafter DIP) on the bracket:
DIP 1 ON - DIP 2, DIP 3, DIP 4, DIP 5 OFF:
set user code number 1 for call from two-residence external unit
(4876KC).
DIP 2 ON - DIP 1, DIP 3, DIP 4, DIP 5 OFF:
set user code number 2 for call from two-residence external unit
(4876KC).
DIP 6, DIP 7, DIP 8: depending on the required functions.
JP1 in position P: sets the monitor bracket as main.
Refer to the table on page 39 for indications regarding settings of
possible configurations. End the riser with terminal Art. 1216 as
shown in the diagram.
Wiring diagram for two-family kit Art. 8185 expanded
with a second 4876KC.
Diagram BK/03BC
Branch connection
Main diagram for two-residence kits Art. 8185.
Refer to the indications on page 36 for the wires to be used and
MT KIT 10
46
the maximum operation distances.
Configuration of microswitches (hereinafter DIP) on the bracket:
DIP 1 ON - DIP 2, DIP 3, DIP 4, DIP 5 OFF:
set user code number 1 for call from two-residence external unit
Page 73
(4876KC).
DIP 2 ON - DIP 1, DIP 3, DIP 4, DIP 5 OFF:
set user code number 2 for call from two-residence external unit
(4876KC).
DIP 6, DIP 7, DIP 8: depending on the required functions.
JP1 in position P: sets the monitor bracket as main.
Refer to the table on the previous pages for indications regarding
settings of possible configurations. By purchasing a switching devi-
ce Art. 1224A and a second external unit Art. 4876KC the two-residen-
ce system can be extended with two external units. The same opera-
tion is possible with the single-residence kits. In systems equipped
with 2 Art. 4876KC, it is possible to view the image from one external
unit or the other alternately ("toggle" function) by pressing the automa-
tic switch-on pushbutton. End the riser with terminal Art. 1216 as
Page 74
shown in the diagram. The max. distance between Art. 1214KC and
the monitor is 20 m.
Diagram BK/03AC
Connection in cascade
Main diagram for two-residence kits Art. 8185.
Refer to the indications given on page 12 for the wires to be used
and the maximum operation distances.
Configuration of microswitches (hereinafter DIP) on the bracket:
DIP 1 ON - DIP 2, DIP 3, DIP 4, DIP 5 OFF:
set user code number 1 for call from two-residence external unit
(4876KC).
DIP 2 ON - DIP 1, DIP 3, DIP 4, DIP 5 OFF:
set user code number 2 for call from two-residence external unit
(4876KC).
DIP 6, DIP 7, DIP 8: depending on the required functions.
JP1 in position P: sets the monitor bracket as main.
Refer to the table on the previous pages for indications regarding
settings of possible configurations. By purchasing a switching device
Page 75
Art. 1224A and a second external unit Art. 4876KC the two-residen-
ce system can be extended with two external units.
The same operation is possible with the single-residence kit. In
systems equipped with 2 Art. 4876KC, it is possible to view the
image from one external unit or the other alternately ("toggle" func-
tion) by pressing video request Pushbutton 2. End the riser with ter-
minal Art. 1216 as shown in the diagram.
Wiring diagram for two-family kit expanded with a
second Art. 4876KC, an additional secondary monitor
and a telephone for each family unit.
Diagram BK/04BC
Branch connection
Wiring diagram for two-family kit expanded with a
second Art. 4876KC, an additional main monitor and a
telephone for each family unit.
Diagram BK/04AC
Connection in cascade
Page 76
Diagram for single-family kit with additional power
feeder Art. 1395
Diagram BK/01/AC
Page 77
Page 78
Page 79
Page 80

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Mt kit 04

Table des Matières