Maintenance and Troubleshooting
8.8
Troubleshooting
Problem
Possible cause
Poor sealing
Sealing bar is dirty
Teflon band is worn out?
Silicon rubber is worn out?
Sealing cylinders are hardly
moving?
No sealing
Sealing wire is broken
Insufficient
Bag is leaking
vacuum in the
bag
Sharp edge perforate the
bag
Bag is too large for the
product
Insufficient
Bad functioning of the
vacuum in the
vacuum pump
chamber
Defective gas pressure
spring
Build-up of
Oil moistened exhaust filter
smoke
element
Operating Instructions - Translation
Solution/remedy
Clean the area under the
sealing bar (brass contact
surface).
Change the Teflon band
Change the silicon rubber
Change Teflon band
Change silicon rubber
Grease piston rod
Replace sealing wire
Use another bag
Use thicker bag
Use smaller bag
Check pump oil level
Change oil
Replace gas pressure spring
Switch off the machine
Unplug the plug from the
socket
Replace the exhaust filter
element