Maintenance and Troubleshooting
8.5
Sealing Wire and Teflon Band Change
Danger!
Electric shock possible!
Pull out the main power plug before starting work!
Danger!
Electric shock possible!
Separate the protruding end so that
there is no contact with the housing of the vacuum tray
-
(danger of a short-circuit)
-
there is no risk of injury.
Operating Instructions - Translation
Pull up the sealing pad away from the sealing
1
cylinders
.
Remove the Teflon strip.
Remove the remains of the sticker using an
appropriate cleaning agent.
1
Loosen the screws located in the front part of
the sealing bar.
Replace the sealing wire.
Screw tight the new sealing wire on one
-
side.
Thread the other end in.
-
Using a pair of pliers stretch the sealing
-
wire and screw the end tight.
Replace the Teflon strip.
Fit the sealing pad back into the device.
8.6
Replacing the Cover Seal a
1
3