7. Connect the product to the power supply and press the on/off switch to put it back
into operation. See also the chapter Commissioning.
7.2.2 Draining the condensate from the compressed air vessel
According to use, but at least once a month, the condensate that forms must be drained
from the compressed air containers.
Fig. 36: Draining the condensate from the compressed air vessel
To do so, proceed as follows:
1. Hold a cup or another suitable vessel under the needle valve (Pos. 1) outlet opening
and open the valve slowly with the other hand.
2. Only close the valve again when just air is escaping.
7.2.3 Visual inspection of the product
A visual inspection of the product must be carried out quarterly.
To do so, proceed as follows:
•
Check the product for signs of damage.
•
A qualified electrician must check all connection cables for damage.
•
Check compressed air connections and hoses for visible damage and leaks.
•
Check the correct setting of the compressed air regulator. The pressure regulator is in
the fan component behind the service plate.