Disposal
11
Disposal
WARNING! Children beware!
!
Before disposing of your old refrigerator:
Dismantle the drawers.
Leave the shelves in place so that the children may not easily
climb inside
➤ Place the packaging material in the appropriate recycling waste bins
wherever possible.
If you wish to finally dispose of the product, ask your local recycling
M
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
12
Troubleshooting
The meaning of the red LED (fig. 2 3, page 3)
For operational faults it illuminates several times. The number of pulses
depends on the type of fault.
Each flash lasts for one quarter of a second. After the series of impulses a
pause follows. The sequence for the fault is repeated every four seconds.
Number of
Fault
flashes
1
Supply voltage
2
Excessive fan current
3
The motor doesn't start
4
Speed too low
5
Overheating of the electron-
ics unit
44
Possible cause
The supply voltage is outside of the set
range.
The fan loads the electronics unit with
more than 1 A.
The rotor is jammed.
The pressure difference in the cooling
system is too high (> 5 bar).
If the cooling system is overloaded, the
minimum speed of the motor of
1850 RPM cannot be maintained.
If the cooling system is loaded too
heavily or the temperature is set too
high, the electronics can overheat.
CD50, CRD50
EN