INSTALLATION
Electrical connection
DC (V)
OUT
This is an (insulation) class II (double insulated) appliance. The
cable does not therefore need to be connected to an earthed
socket.
Check to make sure that the voltage specified on the type plate
matches the mains voltage.
The appliance must be connected to the mains as follows:
BROWN = L (live)
BLUE = N (neutral)
This cooker hood is fitted with a plug. Install the cooker hood so that
the plug is accessible.
Connection to a HRU or CMV unit
Check which connection best suits your ventilation situation. Choose
from the options below of potential free contact or voltage control.
• Use the potential-free connection on the connector block. This
switches your ventilation system to the maximum setting.
• Use the Voltage control signal DC (V). This switches your ventilation
system via the settings on the cooker hood.
Note: When you make a fixed connection to the mains you must make
sure that the live wire is connected to an omnipolar switch with a break
contact distance of at least 3 mm.
max. 100 cm
EN 9