5.3 Locking / Unlocking the microphone
With the microphone locked, it is not possible
a to switch off the microphone; if the POWER
switch (9) is set to OFF with the microphone
locked, the display will show
b to call up the adjusting modes for group /
channel and sensitivity
5.3.1 Activating the locking function
1) Keep the button SET (6) pressed for 2 s until
the display briefly indicates
briefly press the button SET three times again
so that the indication
display (locking deactivated)
2) Press the button
display
3) To save the adjustment, press the key SET The
display will briefly indicate
ing mode will be exited, and the microphone
will go to normal operation
5.3.2 Deactivating the locking function
1) The POWER switch (9) must be set to POWER
2) Keep the button SET (6) pressed for 3 s until
flashes on the display
3) Press the key
(4):
display
4) To save the adjustment, press the button SET
The display will briefly indicate
adjusting mode will be exited, and the micro-
phone will go to normal operation
5.4 Mute function
The mute function is designed for short interrup-
tion of the signal transmission ("throat clearing
mode" or "enquiry mode") with subsequent
immediate readiness for op eration without
delay
All rights reserved by MONACOR
reproduced in any form or by any means for any commercial use.
Then
flashes on the
(5):
flashes on the
, the adjust-
flashes on the
, the
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may be
®
1) Set the MUTE switch (11) at the lower end
of the microphone to the position MUTE If
required, slide the safety cap (10) upwards
beforehand When the mute function is
switched on, MUTE will be shown on the
display of the receiver
2) To continue signal transmission, set the MUTE
switch to the position OFF
Note: In the switch position MUTE, there will be no
speech transmission; however, the microphone will
still be in the transmission mode and consume power
Therefore, always switch off the microphone with the
POWER switch (9) [position OFF] for longer interrup-
tions
6
Specifications
Type of unit:
Directivity:
Radio frequency
range:
Audio frequency
range:
Frequency stability:
Transmitting power:
Ambient temperature: 0 – 40 °C
Power supply:
Dimensions:
Weight:
Subject to technical modification
dynamic hand-held
microphone with PLL
multifrequency trans-
mitter
hypercardioid
518 – 542 MHz, di-
vided into 64 channels
(
table fig 4)
 
50 – 16 000 Hz
±0 005 %
50 mW (EIRP)
two 1 5 V batteries
of size AA (R6)
⌀ 53 mm × 245 mm
370 g