INSTALLATION
3

INSTALLING THE OPERATOR

36mm
210mm
Procedure
Prepare the installation surface
AB
A Rack fastening surface
B
Operator positioning surface
Position the rack in the gate
AB
50
Installation Guide
Assembly positions and levels
75mm
95mm
85mm
C259A
1 Position the ducts (1) for electrical installation.
2 Prepare the holes (2) to anchor the screws,
P275A
1 Secure rack in the gate at a height between 75 mm
40
P275B
The rack is installed at a height between
75 mm and 95 mm. 90 mm is
recommended.
The holes to secure in the ground should
be at a distance of 85 mm relative to the
rack.
respecting the installation levels.
and 95 mm.
90 mm is recommended.