TEST OF THE DISPENSING
MAKE FLUID DISPENSE AT ANY GIVEN TIME
Your equipment is now ready to test the fluid dispense.
Check the settings :
•
The air gauge has to be set or / test value of 20 psi
•
The time button has to be set on 3 or 00,30s
•
The endpoint of the adaptor has to be on the syringe
•
The dispenser must be set to manual.
Keep the syringe at an angle of approximately 45 degrees put the tip
1
slowly on a piece of paper. Press the foot-switch until the fluid comes out
on the paper. Repeat the process every time you replace the tip of the
dispenser.
2
Put the dispenser in manual mode.
3
Hold the syringe and put slowly the nozzle on the test paper. Press the
foot-switch. Check the size of the fluid point. If the point is too small, turn
the button "time" at a lower number. If, on the contrary, the point is too big
set the time at a lower number. Add some points and mark the evolution
of the size of the points on a paper.
also possible to vary by increasing or reducing the air compressed pressure
or by changing the diameter of the needle.
Note : Time is not the only variable which changes the size of the point. It is
65